La prótesis de cadera con recubrimiento de vidrio Primeros resultados con 2 años de evolución
- J. L. VILLAR GONZÁLEZ
- M. FRAGA
- R. LEÓN
- H. R. FERNANDEZ,
- S. MOSQUERA
- J. R. CAEIRO
- C. PÉREZ
- O. MONTERO
ISSN: 0304-5056
Ano de publicación: 1996
Volume: 31
Número: 185
Páxinas: 211-215
Tipo: Artigo
Outras publicacións en: Revista española de cirugía osteoarticular
Resumo
This work analizes the first clinical and radiological results of a cementless hip prosthesis with glass coating at metaphyseal level (CRM prosthesis). A total of 80 arthroplasties implanted since may 1991 to 1994 were studied with a two year follow-up. The clinical assesment was done by the modified Harris score, being satisfactory in 90% of the patients. The radiological study demonstrated good fixation and orientation of the prosthetic compounds in 72 cases. The prosthetic model studied provides a security mechanism both for primary and secondary fixation of the femoral stem and acetabular cup.